PORTABLE PLAYER DOCK

PDX-30/PDX-5O

SERVICE MANUAL

IMPORTANT NOTICE

This manual has been provided for rhe use of aurhorized YAMAHA Reiailers and rheir service personnel,
I! has been assumed rhai basic service procedures inhereni to rhe indusrry. and more specifically YAMAHA Praducis. are already known


and under,

WARN

od by ihe users. and have flierefore not been resulted.
Failure to follow appropriaie service and safeiy procedures when servicing ihis producr may resulr in personal injury
desiruciion Ofexpensive componenis. and failure of ihe producr to perform as specified. For ihese reasons. we advise
all YAMAHA produci owners rhar any service required should be performed by an aurhorized YAMAHA Rerailer or
ihe appoinred service represeniaiive
IMPORTANT: The preseiirauon or sale of th|s manual ro any individual or firm does noi consriuire auiliorizauon. celtificaiion or
recogniuon of any applicable iechnical capabiliiies. or esiablish a pl'lncipleragem reIaiionslup of any form.

"U
U
>.
w
E
"U
U
><
O

The dara provided is believed id be accuraie and applicable io rhe |Im[(s) indicared ou ilie cover. The research engineering. and service
deparunenis of YAMAHA are connnually srriving to improve YAMAHA producrs. Modificaiions are. iherefore. iiieviiable and
specificarions are subyecr io change wirhoui norice or Obligallon io rerrorii. Should any discrepancy appear ro exisr. please coniacr Ihe
disiriburor's Service Division,

WARNIN

: Sraiic discharges can desiroy expensive componenrs Discharge any siaiic elecrriciry your body may have
accumulared by grounding yourselfio rhe ground buss in rhe unit (heavy gauge black wires connecr io ihis buss).

IMPORTANT: Turn rhe uml OFF during disassembly and pari replacemeni, Recheck all work before you apply power io ilie unir.

I CONTENTS

To SERVICE PERSONNEL
FRONT PANELS
REAR PANELS . 7
REMOTE CONTROL PANEL ...8
SPECIFICATIONS / afilfli 8-9
INTERNAL VIEW 9
ABOUTTHE STATUS INDICATOR /

17--914>:)r-9-

2-3
4-5
6-


10

:wV-tx7217A/1g 137-7zafimfiimilfifi I/Tuin
This Service Manual uses recycled papal.

Copyllgm © 2009 VAMAHA CORPORATION All nghls reserved.
Thls manual is copyrighted by YAMAHA and may not be copled or
redistributed euher m mm! or elecuonically wuhoui permission,

DISASSEMBLY PROCEDURES / {angina 11-13
Ic DATA
BLOCK DIAGRAM
PRINTED CIRCUIT BOARDS
PIN CONNECTION DIAGRAMS 20
SCHEMATIc DIAGRAMS 21-22
REPLACEMENT PARTS LIST . 23-31
REMOTE CONTROL .


fiYAMAHA

YAMAHA CORPORATION

P.O.Box 1, Hamamatsu. Japan
animate 09.02

Page 2

o
3
X
D
D.
\
o
1
X
D
D.

PDX-30lPDX-50

I TO SERVICE PERSONNEL

Critical Components Information

Components having special Characteristics are marked A
and must be replaced with parts having specifications equal
to those originally installed.

2. Leakage Current Measurement (For 120V Models Only)
When service has been completed, it is imperative to verify
that all exposed conductive surfaces are properly insulated
from supply circuits.

- Meter impedance should be equivalent to 1500 ohms
shunted by 0.15 pF.

AC LEAKAGE
WALL EQUIPMENT TESTER OR
OUTLET UNDER TEST EQUIVALENT

@ID-

J:

INSULATING
TABLE

- Leakage current must not exceed 0.5mA.
0 Be sure to test for leakage with the AC plug in both polarities.

CAUTION"
EB Ft: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 40A, 15v
7L" FUSE.
CAUTION

F1: REPLACE WITH SAME TYPE 40A, 15V FUSE.

ATTENTION

F1: UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 40A, 15V.

WARNING: CHEMICAL CONTENT NOTICE!

This product contains chemicals known to the State of California to cause cancer, or birth defects or other reproductive

harm.

DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REASON

WHATSOEVER!

Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or

expose eyes to solder/flux vapor!

If you come in contact with solder or components located inside the enclosure of this product, wash your hands before

handling food.

About lead free solder l fifinl \DfiIZ'DLT

All of the P.C.B.s installed in this unit and solder joints are
soldered using the lead free solder.

Among some types Of lead free solder currently available,
it is recommended to use one of the following types for
the repair work.

0 Sn + Ag + Cu (tin + silver + copper)

0 Sn + Cu (tin + copper)

0 Sn + Zn + Bi (tin + ZlnC + bismuth)

Caution:
As the melting point temperature of the lead free solder
is about 30°C to 40°C (50°F to 70°F) higher than that of
the lead solder, be sure to use a soldering iron suitable
to each solder.

$f§§li%§fi$th\é S/S-ngffiéo CIQUI \/ @HHIZ
i éifiégfilifififil \\/ JTV \\/ @HHiiLThifil
fii/cl/ \VGYKIZIZIL < ObUfiéifibE U $373K IETEBTIIIC
IiFEEUDJi 5 7.1mm V/ @UDEEHEIEE Lifil

- Sn+Ag+Cu (3% + E + 313)

- Sn+Cu (fiJrfiEI)

- Sn+Zn+Bi ($5 + fiiu + EX?X)
512% i
fifia/ \7 gflfififiifigfififiwfidfl U / \\/ iIZttfi 30 ~
4O°C7F§I§E < 7;: DCmifiw'fi %h?h®l V/fillfio
tnyfiéfaéfifl<fiem