Yamaha htr 6250

This is the 150 pages manual for yamaha htr 6250.
Read or download the pdf for free. If you want to contribute, please mail your pdfs to info@audioservicemanuals.com.

Page: 1 / 150
left right
yamaha htr 6250

Extracted text from yamaha htr 6250 (Ocr-read)


Page 1

AV RECEIVER/AV AMPLIFIER

RX-V565/HTR-6250/
AX-V565

SERVICE MANUAL

N

>.<

5
>
>53
<1
g-l
01-3
m
N
01
Q

IMPORTANT NOTICE

This manual has been provided for (he use of alllhOI'iZed YAMAHA Retailers and their service personnel,


II has been assumed that basic service procedures inhereni i0 ihe indusrry. and more specifically YAMAHA Products. are already known
and understood by Ihe use ,r and have rherelnre not been resiaied,

WARNI

Failure to follow appropriaie service and safety procedures when servicing this produci may resulr in personal injury
desiruciion or expensive conipoiienis. and failure of ihe produci to perform as speCIfied. For these reasons. we advise
all YAMAHA produci owner-s iliai any service required should be performed by an authorized YAMAHA Reiailer or
Ihe appoimed sel'VIce represeillalive
IMPORTANT: The presenraurm or sale of this manual in any individual or firm does not consrilllre authorizarlon. cenificarion or

recngnilion of any applicable technical capabilities. or esiablish a pl'incipleeagem relaiionship of any form
The daia provided is believed lo be accurate and applicable in ihe unins) indicaiea on the cover, The research, engineering. and service
deparnnenis or YAMAHA are coniinually slriviilg to improve YAMAHA pl'oducls, Modifications are. iherer'oi-e. inevitable and
specifications are SubjeCI to change without norice or obligation to react Should any discrepancy appear to exi dislribulor's Service Division,
WARN NC: Siatic discharges can destroy expensive components Discharge any static electricity your body may have
accumulaied by grounding yourselrio ilie ground buss in the unit (heavy gauge blach wires conueci io Ihis buss).

IMPORTANT: Turn ihe unii OFF during disassembly and part replacement. Reclleck all work before you apply power to the uml.

I CONTENTS

TO SERVICE PERSONNEL 2
FRONT PANELS
REAR PANELS .
REMOTE CONTROL PANEL
SPECIFICATIONS / afilfli 10-16
INTERNAL VIEW
SERVICE PRECAUTIONS I fi-Ezlfiwifiégifi .....17
DISASSEMBLY PROCEDURES/meal: . 18-20
UPDATING FIRMWARE/

7 7-137 Irmgarsbas 21-32
SELF-DIAGNOSTIC FUNCTION /

$1477 (Eaewmaa 33-66


:wv-EXVzlmmc 137-7zafimfiimilfilfi I/Tuin
This Service Manual uses IeCycled paper.

101133

Copyrighi © 2009 YAMAHA CORPORATION All rigbis reserved.
This manual is copyrighied by YAMAHA and may not be copied or
Iedlsirlbuled enter in prim or elecironicallv vvimoui pemllSSIOn

DISPLAY DATA 67-68
Ic DATA
PIN CONNECTION DIAGRAMS
BLOCK DIAGRAMS

PRINTED CIRCUIT BOARDS ................................94-111
SCHEMATIc DIAGRAMS 113-124
REPLACEMENT PARTS LIST . 125-143
REMOTE CONTROL . 144-146
ADVANCED SETUP / tfimefifiE-Efiia . 147-148

fiYAMAHA

YAMAHA CORPORATION

P.O.Box 1, Hamamatsu, Japan
animate 09.03

Page 2

AX-V565

B
In
N
9
m
._
E
In
In
In
>.
X
m

RX-V565/HTR-6250/AX-V565

I TO SERVICE PERSONNEL

.Critical Components Information

Components having special characteristics are marked A and
must be replaced with parts having specifications equal to those
originally installed.

2. Leakage Current Measurement (For 120V Models Only)
When service has been completed, it is imperative to verify
that all exposed conductive surfaces are properly insulated
from supply circuits.

0 Meter impedance should be equivalent to 1500 ohms shunted
by 0.15 uF.

For U model
IE9 CAUTION

AC LEAKAGE
WALL EQUIPMENT TESTER OR
OUTLET UNDER TEST EQUIVALENT

@ID-

J:

INSULATING
TABLE

- Leakage current must not exceed 0.5mA.
0 Be sure to test for leakage with the AC plug in both polarities.

*Aiv F3701: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 6A,

125V FUSE."

For C model
CAUTION

F3701: REPLACE WITH SAME TYPE 6A, 125V FUSE.

ATTENTION

F3701: UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 6A, 125V.

WARNING: CHEMICAL CONTENT NOTICE!

This product contains chemicals known to the State of California to cause cancer, or birth defects or other reproductive

harm.

DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REASON

WHATSOEVER!

Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or

expose eyes to solder/flux vapor!

If you come in contact with solder or components located inside the enclosure of this product, wash your hands before

handling food.

About lead free solder l fiflal \DfiIZ'DLT

All of the P.C.B.s installed in this unit and solder joints are
soldered using the lead free solder.

Among some types of lead free solder currently available,
it is recommended to use one of the following types for
the repair work.

0 Sn + Ag + Cu (tin + silver + copper)

0 Sn + Cu (tin + copper)

0 Sn + Zn + Bi (tin + Zinc + bismuth)

Caution:
As the melting point temperature of the lead free solder
is about 30°C to 40°C (50°F to 70°F) higher than that of
the lead solder, be sure to use a soldering iron suitable
to each solder.

$t§§ll%§i$hfb\é?NT®§l&£$Ul \/ filfllfl:
meeelzlmaex \y/JTV \ysflnlfirhfmim
fifil/ \yéiltlztln < amfifiofi U $335 léflifirfil:
liTEEUJot 5 tiilfifia/ \) fiiUJIEfiHEIEIEé LEE

- Sn+Ag+Cu (fl + E + 31%)

- Sn+Cu (fi +313)
- Sn+Zn+Bi ($5 + fififi + EX?X)

52$ 2

Alia/Ell \y gimfitfi-EE Eliiéfimaik U l \y silzlEt/x 30 ~
40°CEI§FE§ < 7:: a mafia)? %n%h®/ 071:6:
t/ wfibfélfififi < fifirv