Page 1

AV RECEIVER/AV AMPLIFIER

RX-V1700/DSP-AX1700

SERVICE MANUAL

/

contact the distributors Service Division

\

I CONTENTS

TO SERVICE PERSONNEL .......................................... 2
FRONT PANELS ............................................................ 3
REAR PANELS .......................................................... 4-6
REMOTE CONTROL PANELS ...................................... 7
SPECIFICATIONS / 55%1i1li .................................. 8-10
INTERNAL VIEW ......................................................... 11
DISASSEMBLY PROCEDURES I fifigfielflfi .......... 12-1 7
UPDATING FIRMWARE/

77-A717®§§3&J$ ..................................... 18-19
SELF DIAGNOSIS FUNCTION (DIAG) /

E EEQDHEEE (5M 77) ..................................... 20-54

:mi-Iixv:;7»m 1:: v-flRTEofiifietim Liven
This Service Manual uses recycled paper.

101021

IMPORTANT NOTICE

This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel.
It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA Products, are already
known and understood by the users. and have therefore not been restated.

WARNING: Failure to follow appropriate service and safety procedures when servicing this product may result in personal
injury, destruction of expensive components, and failure of the product to perform as specified. For these reasons,
we advise all YAMAHA product owners that any service required should be performed by an authorized
YAMAHA Retailer or the appointed service representative.

IMPORTANT: The presentation or sale of this manual to any individual or firm does not constitute authorization, certification or
recognition of any applicable technical capabilities, or establish a principle-agent relationship of any form.

The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and
service departments onAMAHA are continually striving to improve YAMAHA products. Modifications are, therefore, inevitable
and specifications are subject to change without notice or obligation to retrofit. Should any discrepancy appear to exist, please

WARNING: Static discharges can destroy expensive components. Discharge any static electricity your body may have
accumulated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss).
IMPORTANT: Turn the unit OFF during dis-assembly and part replacement, Recheck all work before you apply power to the unit.

@2006 YAMAHA CDRIOMTEON All rights reserved
This manual IS copyi igrited by YAMAHA and may not be copied or
redistributed either in print or electronically Without permissmri

\

/

AMP ADJUSTMENT / 7>7°EB§EIE ........................... 55
DISPLAY DATA ........................................................... 56
IC DATA ................................................................. 57-68
BLOCK DIAGRAMS ............ .. 69-71
PRINTED CIRCUIT BOARDS ................................ 72-99
PIN CONNECTION DIAGRAMS ........................ 100-102
SCHEMATIC DIAGRAMS .................................. 103-118
REPLACEMENT PARTS LIST. 119-154
REMOTE CONTROL .......................................... 155-157
ADVANCED SETUP I

77H/x>1i~twy i7~y7x:1-&§£E?e ..... 158-160

.YAMAHA

YAMAHA CORPORATION

P,O,Box1, Hamamalsu, Japan
I 06.09

D
m
'P
>
><

N
O
D

lOOLI-A'XH

Page 2

\ o
8 E RX-V1700/DSP-AX1700
I 1-
,. ><
> at
Ea
o I TO SERVICE PERSONNEL ACLEAKAGE
-- - WALL EQUIPMENT TESTER OR
1. Critical Components Information _ _
Components having special characteristics are marked & OU [LET UNDER FEST EQUIVALENT
and must be replaced with parts having specifications equal
to those originally installed. ® :ID-
2. Leakage Current Measurement (For 120V Models Only) J_-
When service has been completed, it is imperative to verify _
that all exposed conductive surfaces are properly insulated INSEALéAG-EING

from supply circuits.

0 Meter impedance should be equivalent to 1500 ohms shunted o Leakage current must not exceed 0.5mA.

by 0.15uF. 0 Be sure to test for leakage with the AC plug in both polarities.
CAUTION
.3, F1, F2: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 10A,
_A_V 125V FUSE."
CAUTION
F1, F2: REPLACE WITH SAME TYPE1OA, 125V FUSE.
ATTENTION

F1, F2: UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 10A, 125V.

WARNING: CHEMICAL CONTENT NOTICE!

The solder used in the production of this product contains LEAD. In addition, other electrical/electronic and/or plastic (where
applicable) components may also contain traces of chemicals found by the California Health and Welfare Agency (and
possibly other entities) to cause cancer and/or birth defects or other reproductive harm.

DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REA-
SON WHATSOEVER!

Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose
eyes to solder/flux vapor!

If you come in contact with solder or components located inside the enclosure of this product, wash your hands before
handling food.

About lead free solder / fifififl / 5? I: OL \ T

$l§§lll§$§3fltM§§Nt®ElfiEofi UV \ygffiljllcliéififi
steam) \JST/ \y9tfiljéfltb)iio

fifin) \yfilClaflA < DDODtéiEDE) D i??? iléfffififilllatTEEUD
cl: 5 male) \VfiODlfifii Eiflfi Ciel

- Sn+Ag+Cu(§%+$E+i-lfi)

All of the P.C.B.s Installed in this unit and solder joints are
soldered using the lead free solder.

Among some types of lead free solder currently available,
it is recommended to use one of the following types for the
repair work.

. Sn + Ag + Cu (tin + silver + copper)
- Sn + Cu (tin + copper)
. Sn + Zn + Bi (tin + zinc + bismuth)

Caution:
As the melting point temperature of the lead free solder is
about 30°C to 40°C (50°F to 70°F) higher than that of the lead
solder, be sure to use a soldering iron suitable to each solder.

- Sn+Cu(§5+$fl)
- Sn+Zn+Bi(§%+fifii:l+l:"7\77\)

fig :
$1133) \ysionataierslaseewtexo; \JfilltljKSOrvleC
EEE ETECIEIEH < Edit/)0