Sharp cd cpm 4000w sm

This is the 83 pages manual for sharp cd cpm 4000w sm.
Read or download the pdf for free. If you want to contribute, please mail your pdfs to info@audioservicemanuals.com.

Page: 1 / 83
left right
sharp cd cpm 4000w sm

Extracted text from sharp cd cpm 4000w sm (Ocr-read)


Page 2

CD-M4000W/CP-M4000

SAFETY PRECAUTION FOR SERVICE MANUAL

WARNINGS
THE AEL (ACCESSIBLE EMISSION LEVEL) OF THE LASER POWER OUTPUT IS LESS THAN CLASS 1 BUT THE LASER
COMPONENT IS CAPABLE OF EMITTING RADIATION EXCEEDING THE LIMIT FOR CLASS 1. THEREFORE IT IS
IMPORTANT THATTHE FOLLOWING PRECAUTIONS ARE OBSERVED DURING SERVICING TO PROTECT YOUR EYES
AGAINST EXPOSURE TO THE LASER BEAM.
1-WHEN THE CABINET IS REMOVED, THE POWER ISTURNED ON WITHOUTA COMPACT DISC IN POSITION AND THE
PICKUP IS ON THE OUTER EDGE THE LASER WILL LIGHT FOR SEVERAL SECONDS TO DETECT A DISC. DO NOT
LOOK INTO THE PICKUP LENS.
2-THE LASER POWER OUTPUT OF THE PICKUP UNIT AND REPLACEMENT SERVICE PARTS ARE ALL FACTORY
PRESET BEFORE SHIPMENT.
DO NOT ATTEMPT TO READJUST THE LASER PICKUP UNIT DURING REPLACEMENT OR SERVICING.
3-UNDER NO CIRCUMSTANCES STARE INTO THE PICKUP LENS AT ANY TIME.
4-CAUTION-USE OF CONTROLS 0R ADJUSTMENTS, OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE
SPECIFIED HEREIN MAY RESULT IN HAZARDOUS RADIATION EXPOSURE.

mmmmtmmmmmummmmnmmmm
EflflIIgInummflmmmmmmmmnm%%
mmmmnmmmmnnmmmmmmmmnm

UUUUHHUDDUUD
UDDUHHDUUUD ...~ 0

DUEL?
unuflnnnfluflnflnofluu ,
unonunnoqu t,
ln°nnDIIW l
nu0nufl U 0 0


ELASS I L_ASER PRODUCT
APPAREIL A LASER IJE BLASSE I

PRODUCTO LASER DE CLASE I

Laser Diode Properties
Material: GaAlAs
Wavelength: 780 nm
Emission Duration: continuous
Laser Output: max. 0.6 mW

cwritmnwtsiau LAM RADIATION HI-)4 OPEN Do nor STAKE IN'IKJBEAVI
0R vmw DIRELTLY WH'H OPTICAL INbI'RLMI-LVTS

VARI\II\'Cr NLK; LAsERsrRAmiNG NAR DhNNA DEL AR ()WNAD IsIIkkAH
IN I 5mm (xH BEI'RAKI'A I-J >1!th MILD ()PmKA INSTRL'MLW

ADVERSEL uswut; LAsEksmALwt; vw Ammo 51-; mm IND l
xm NthLLLR IKKE MED ()PIISKE INSIRUMI-VTER
mm AVArrALst om' AL'I'IIINA NAKvam LASERSATHLYLLE ALA

Tuuom SAtkEsu-N ALAKA mm IA ()PIISEN LAI'ITI:EI\ LAPl

VARMR ' u Loam-rm 'AR 0mm um. AR ()PPNAD smuu E!
w I 5m H BEI'RAKTA , V (ii-340M ()PI'LSKI msmuvtmr
ADVERSELLSYKLIG L-xskxsrRAuN AR DEKSEL APNu STIRRIKKI: KW I
szLkN hLLhR SL Dim-.Kn; MED ()PIISKI: IVSIRUMENTER

VOLTAGE SELECTION

Before operating the unit on mains, check the preset voltage. ll the voltage is different from your local voltage, adjust the voltage

as follows.
Turn the selectorwith a screwdriver until the appropriate voltage number appears in the window (1 10 V, 127 V, 220 V or 230 V-24O V AC).

-2-