Sansui SE 88 Service Manual

This is the 16 pages manual for Sansui SE 88 Service Manual.
Read or download the pdf for free. If you want to contribute, please mail your pdfs to info@audioservicemanuals.com.

Page: 1 / 16
left right
Sansui SE 88 Service Manual

Extracted text from Sansui SE 88 Service Manual (Ocr-read)


Page 1

SERVICE MANUAL

FULL REMOTE CONTROL SYSTEM
COMPU-EQUALIZER

SANSUI SE-BB

CAUTION

'l . Parts identified by theAsymbol on the schematic
diagram and the parts list are critical for safety.
Use only replacement parts that have critical charac-
teristics recommended by the manufacturer.

2. Make leakagecurrent or resistance measurements
to determine that exposed parts are acceptably in-
sulated from the supply circuit before returning the
appliance to the customer.

SANSUI ELECTRIC CO., LTD.

'SPECIFICATIONS

Input sensitivity and impedance (1 kHz)
INPUT, TAPE PLAY-1,2
............................. lSOmV/47 kohms
Output level and impedance (1 kHz)
TAPE REC-1,2 ............. 150mV/l.5 kohms
OUTPUT .................... 150mV/l.5 kohms
(Maximum output level: 5V into 47 kohms at 0.5%
total harmonic distortion)
Total harmonic distortion (2V, 20 Hz to 20 kHz)
lNPUT, TAPE PLAY-1,2
............................. 0.008%
Frequency response (at 0.5V, Equalizer controls: 0 position)
INPUT, TAPE PLAY-1,2
............................. 10 Hz to 100 kHz,
+ l.0 dB, --3.0 dB
Signal to noise ratio (Short-circuit, A-network)
lNPUT, TAPE PLAY-1,2
............................. 110 dB

Equalizer frequency ........ 25 Hz, 50 Hz, 100 Hz,

160 Hz, 250 Hz, 400 HZ,
630 Hz, 1 kHz, 1.6 kHz,
2.5 kHz, 4 kHz, 6.3 kHz,
10 kHz, 20 kHz

Level variation range....... :e 10 dB

Others
Power voltage ................. 120, 220, 240 V
(50/60 Hz)
For U.S.A. and Canada
............................. 120 V (60 Hz)
, Power consumption ........ 20 watts
Dimensions ..................... 430 mm (16-15/16') (\N)

111 mm (4-3/8" )(H)

303 mm (ll-15116") (D)
Weight ............................ 4.l kg (9.0 lbs) net

5.5 kg (12.0 lbs) packed

Design and specifications subiect to change withOut notice for im-
provements.

Due to local laws and regulations, is unit sold in some areas are not
equipped with variable voltage sch-Cb. .