Pioneer vsxd 307 service manual

This is the 52 pages manual for pioneer vsxd 307 service manual.
Read or download the pdf for free. If you want to contribute, please mail your pdfs to info@audioservicemanuals.com.

Page: 1 / 52
left right
pioneer vsxd 307 service manual

Extracted text from pioneer vsxd 307 service manual (Ocr-read)


Page 1

2 VSX-D307 1. SAFETY INFORMATION This service manual is intended for qualified service technicians ; it is not meant for the casual do-it- yourselfer. Qualified technicians have the necessary test equipment and tools, and have been trained to properly and safely repair complex products such as those covered by this manual. Improperly performed repairs can adversely affect the safety and reliability of the product and may void the warranty. If you are not qualified to perform the repair of this product properly and safely, you should not risk trying to do so and refer the repair to a qualified service technician. WARNING Lead in solder used in this product is listed by the California Health and Welfare agency as a known reproductive toxicant which may cause birth defects or other reproductive harm (California Health & Safety Code, Section 25249.5). When servicing or handling circuit boards and other components which contain lead in solder, avoid unprotected skin contact with the solder. Also, when soldering do not inhale any smoke or fumes produced. NOTICE (FOR CANADIAN MODEL ONLY) Fuse symbols (fast operating fuse) and/or (slow operating fuse) on PCB indicate that replacement parts must be of identical designation. REMARQUE (POUR MODéLE CANADIEN SEULEMENT) Les symboles de fusible (fusible de type rapide) et/ou (fusible de type lent) sur CCI indiquent que les pices de remplacement doivent avoir la mme dŽsignation. ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED BEFORE RETURNING THE APPLIANCE TO THE CUSTOMER. 2. PRODUCT SAFETY NOTICE Many electrical and mechanical parts in the appliance have special safety related characteristics. These are often not evident from visual inspection nor the protection afforded by them necessarily can be obtained by using replacement components rated for voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in this Service Manual. Electrical components having such features are identified by marking with a on the schematics and on the parts list in this Service Manual. The use of a substitute replacement component which does not have the same safety characteristics as the PIONEER recommended replacement one, shown in the parts list in this Service Manual, may create shock, fire, or other hazards. Product Safety is continuously under review and new instructions are issued from time to time. For the latest information, always consult the current PIONEER Service Manual. A subscription to, or additional copies of, PIONEER Service Manual may be obtained at a nominal charge from PIONEER. 1. SAFETY PRECAUTIONS The following check should be performed for the continued protection of the customer and service technician. LEAKAGE CURRENT CHECK Measure leakage current to a known earth ground (water pipe, conduit, etc.) by connecting a leakage current tester such as Simpson Model 229-2 or equivalent between the earth ground and all exposed metal parts of the appliance (input/output terminals, screwheads, metal overlays, control shaft, etc.). Plug the AC line cord of the appliance directly into a 120V AC 60Hz outlet and turn the AC power switch on. Any current measured must not exceed 0.5mA. (FOR USA MODEL ONLY) Leakage current testerReading should not be above 0.5mA Device under test Test all exposed metal surfaces Also test with plug reversed (Using AC adapter plug as required)Earth ground AC Leakage Test

Page 2

3 VSX-D307 Mark No. Symbol and DescriptionPart No. Remarks VSX-D307/KUXJ VSX-D307/KUXJI VSX-D307/KCXJI 3 Operating Instructions (English) ARB7136 ARB7136 Not used 3 Operating Instructions (English/French) Not used Not used ARE7159 NSP 4 Warranty Card ARY1051 ARY1051 ARY1075 11 Packing Case AHD7595 AHD7557 AHD7582 2.1 PACKING 1 FM Antenna ADH7004 2 AM Loop Antenna ATB7009 3 Operating InstructionsSee Contrast table (2) NSP 4 Warranty CardSee Contrast table (2) 5 Remote Control Unit AXD7161 (CU-VSX124) 6 Battery Cover RZN1156 NSP 7 Dry Cell Battery (R6P, AA) VEM-013 8 Left Pad AHA7203 9 Right Pad AHA7204 10 Packing Sheet AHG1218 11 Packing CaseSee Contrast table (2) 12 Polyethylene Bag Z21-038 (0.03´230´340) (1) PACKING PARTS LIST Mark No. Description Part No. 2. EXPLODED VIEWS AND PARTS LIST NOTES: · Parts marked by "NSP" are generally unavailable because they are not in our Master Spare Parts List. · The mark found on some component parts indicates the importance of the safety factor of the part. Therefore, when replacing, be sure to use parts of identical designation. · Screws adjacent to mark on the product are used for disassembly. 1 2 4 3 5 712 8 (1/2) 9 (1/2) 9 (2/2) 8 (2/2) 6 10 11 (2) CONTRAST TABLE VSX-D307/KUXJ, KUXJI and KCXJI are constructed the same except for the following : FM Antenna : ADH7004 AM Loop Antenna : ATB7009 Dry Cell Battery : VEM-013 (size ÒAAÓ IEC R6P) ´ 2 Remote Control Unit (CU-VSX124 : AXD7161) Accessories AV MULTI-CHANNEL RECEIVER REMOTE CONTROL UNIT DIRECT FUNC. VIRTUAL RECEIVERSTANDBY/ON TVCONTROL LD DVD TUNER MPX STANDBY/ON CLASS D.ACCESS TAPE TV FUNC.BAND CDSOURCE SELECT LOUD. PRO LOGIC SURROUND DSP MODE TV VOL. FREQ. 0 789 456 123 MUTING MASTER VOLUME CENTER LEVEL CD DISC EFFECT CENTER MODE DELAY TIME TEST TONE REAR LEVEL CHANNEL STATION