Philips hdd 084 service manual

This is the 31 pages manual for philips hdd 084 service manual.
Read or download the pdf for free. If you want to contribute, please mail your pdfs to info@audioservicemanuals.com.

Page: 1 / 31
left right
philips hdd 084 service manual

Extracted text from philips hdd 084 service manual (Ocr-read)


Page 2

1.0 TECHNICAL SPECIFICATION and SERVICE HINTS 8. Once the GoGear micro jukebox is disconnected from the computer, the display will show Firmware Upgrading for a couple of seconds and then start up as usual. If the message does not disappear after 2 minutes, do a soft reset by pressing and holding the  key and the volume + key for a couple of seconds. For HDD085/HDD082 1. Download the latest version of the Device Manager application from http://www.philips.com/support. You may need to enter your language preference and the model number e.g. hdd085, to access the Device Manager application upgrade file. 2. Double click the downloaded execution file to start the installation of the Device Manager. 3. Connect the GoGear to the power supply with the AC/DC adapter and to the computer with the provided USB cable. Make sure that Windows Media Player along with any other applications are closed. 4. Launch the Philips Device Manager by double clicking the Device Manager icon at the task bar on your computer. 5. The Philips Device Manager will detect the connection of your GoGear and the application will automatically check on the server to see if an update is available and prompt user to download the updated firmware. Click YES to start the downloading. 6. A status bar will show the downloading progress of the firmware. Once the downloading is complete the application will prompt you to install the update onto your GoGear. Click YES to confirm 7. The application will show the status of updating and at the end you need to click OK to complete the update. (Please do not disconnect the jukebox during the upgrading process as this interruption may damage the firmware!) 8. Once the success message is displayed. Close Device Manager and all opened application and unplug your GoGear. Service Hints Rebuild database & firmware after replacement of hard disk drive IMPORTANT: All devices having the hard disk replaced must have the firmware image & database rebuilt before returning to customers. After the replacement of hard disk the database and firmware image must be rebuilt in the device with device manager by following the procedure below. For HDD084 1. Connect the GoGear to the power supply with the