Page 2

P/l"l3'l-900ll DC Voltage MeaSureinent

:lngc' Item Voltge Instrument Remarks
V l l-DC Supply 1 +32V Digital meter or multimeter Standard input AC source
_ --D(, Supply l 7732V Digital meter or multimeter Standard input AC source
7:} lDC Supply 2 +24V Digital meter or multimeter
4 7DC Supply 2 A24V Digital meter or multimeter
D 5 l Vccl +24V Digital meter or multimeter
D 6 er01 724V Digital meter or multimeter
7 che2 -l-15V Digital meter or multimeter
g8 ~Vec2 ~15V Digital meter or multimeter
9 Relay Von +13V Digital meter or multimeter Power on +18V, after Ssee down to 13V
A l() lliono Him: ~I-23.5V Digital meter or multimeter
ll lliono "V(( -~23.5V Digital meter or multimeter'
ND 'l'one ~l Vrc +235V Digital meter or multimeter
77777 Ll 'l'one 'VtC =~23.5V Digital meter or multimeter
[/1 Control ICB aerce +14V Digital meter or multimeter
15 Control PCB 0V 0V Digital meter or multimeter
VHS Working W -l l3.5V Digital meter or multimeter When power off +13.5V down to 0V in 0.5 sec
T Memory V l7 +l4,zl\7 Digital meter or multimeter 10 minutes after power off must higher then 5V