Service Information S500i
Circuit Change
PROBLEM: It is possible that recently delivered S500I product has incorrect
fuse type fitted .
CAUSE: It is a fast blow instead of a slow blow time delay fuse which may be
present.
SOLUTION: To prevent premature fuse failure please change the incorrect
fuse to the correct fuse. The current and voltage rating is the same. See below
for correct type.
Incorrect type - F250mA 250v or 250mA 250v
Correct type - T250mA 250v (Time Delay/Slow Blow)
Contact:
NAD Electronics International
633 Granite Court
Pickering, ON Canada L1K 3K1