Kenwood P 110 Service Manual

This is the 6 pages manual for Kenwood P 110 Service Manual.
Read or download the pdf for free. If you want to contribute, please mail your pdfs to info@audioservicemanuals.com.

Page: 1 / 6
left right
Kenwood P 110 Service Manual

Extracted text from Kenwood P 110 Service Manual (Ocr-read)


Page 1

2 P-110 1. Speed adjustment First, adjust the 33 RPM by 33 trimming pot. then the 45 RPM by trimming pot in the motor from bottom case with the stroboscopic disk. 1. 33rpm MM.AMP OFF ON 33RPM 45RPM ADJUSTMENT Note :PCB figure is not available in this manual. P-110 98.12.15 10:57 y[W 2

Page 2

+B LINE -B LINE 1u50C7 + R2 1KR3 4702 38 41C6 + 3.3u50R8 1K 100KR18 4.7KR1 100PC2 390KR6 33KR5 2200PC4 8200PC3 100KR7 330R4 10u25C1 + 6 5 7 C8 100P 2200PC10 C11 8200PR14 390K 33K R13 C5 1u50+ R9 1KR11 4703.3u50C13 +1K R16 4.7KR10 R20 100KR17 100K R19 100K 10u25 330 R12 C9 +ON OFF L IN GND R IN Lch Rch 220u16C18 + 220u16C17 + 10u25C15 +100R21 0.022C14 GND IN OUT T. F. 11 5 33 1/3 r.p.m 45 r.p.m 33 45 WHT GND +B BLK250mAFUSE 1000u16C16 +BLU BLU AC10.5VBRN BLUAC CORD RED +13.6V +13.6V +13V +9V +13.6V +13.6V +13.6V +8.6V +8.6V +8.6V+8.6V +8.6V 100KR15 L OUT GND R OUT BLU 0V 240V 240V 11 5T. F. BRN BLU 100VAC120V/240V BRN AC CORDGND LINE SIGNAL LINE +B -B M.M. AMP (2/2)SW1OUTPUT (PIN CORD) M.M. AMPLch Rch D5 D2 D1 D4 D3 SW3 SPEED (SW) SPEED ADJ. SW2 POWER SW (LEAF SW)IC1(1/2) IC1 SW4 IC1 : NJM4558L IC2 : NJM78L09A D1-4 : 1N4002 M.M. CARTRIDGE IC2 MOTOR ASS'Y TRANSFORMER AC POWER P.C.B. P-110 POWER EQ MM AMPLIFIER AC POWER P.C.B. TRANSFORMER POWER (OTHER) (M) TYPE 8.6V 13.6V 9.0V 13.0V 7 2 1 3 5 4 6 Y21-3360-00 P-110 CAUTION: For continued safety, replace safety critical components only with manufacturer's recommended parts (refer to parts list). indicates safety critical components. For continued protection against risk of fire, replace only with same type and rating fuse(s). To reduce the risk of electric shock, leakage-current or resistance measurements shall be carried out (exposed parts are acceptably insulated from the supply circuit) before the appliance is returned to the customer.The DC voltage is an actual reading measured with a high impedance type voltmeter at 33-1/3 r. p. m. mode. The measurement value may vary depending on the measuring instruments used or on the product. NTM4558L NJM78L09A ABDCE P-110 98.12.15 10:57 y[W 3