Heathkit IM 48 Manual

This is the 19 pages manual for Heathkit IM 48 Manual.
Read or download the pdf for free. If you want to contribute, please mail your pdfs to info@audioservicemanuals.com.

Page: 1 / 19
left right
Heathkit IM 48 Manual

Extracted text from Heathkit IM 48 Manual (Ocr-read)


Page 1

Page 2

Frequency ReSponse:

AC VTVM

Sensitivity:
AC VTVM
Wattmeter. .

LM, Analyzer

Range:
AC VTVM

DBM

......

Wattmeter

LM. Analyzer

Input Impedance:
AC VTVM

Wattmeter

Output Impedance

--......-........

Wattmeter. . . . . . . . . . .
l.M, Analyzer High Pass Filter. . . .
I.M. Analyzer Low Pass Filter. . . ,

-....-....

........

...-......

I.M. Analyzer

........

HEATHKIT

SPECIFICATIONS

Low and High Frequency Output. . . . . . .

Internal Generator Frequencies:

Low Frequency............
HighFrequency............

Accuracy:

AC VTVM and Wattmeter

l_M, Analyzer

.........-...

...-....-........-....

10 cycles to 100 kc :1 db.
10 cycles to 50 kc :1 db,
2000 cps to 12000 cps.

10 cps to 600 ops,

10 millivolts full scale maximum.

.15 milliwatts full scale maximum.

.04 volts minimum high frequency signal re-
quired or .17 volts of LF and HF energy mixed
4:1.

.01, .03, .1, .3, 1, 3, 10, 30, 100, 300 volts RMS
full scale.

-40, -30, -20, -10, 0, +10, +20, +30, +40, +50
reads from -65 to +52 dbm,

.15 mw, 1,5 mw, 15 mw, 150 mw, 1.5 w. 15 w,
150 w full scale. Maximum continuous power 25
watts, intermittent power to 50 watts.

1%, 3%, 10%, 30%, 100% full scale.

1 megohm or 4, 8, 16 or 600 (2, switch selected,
1 megohm or 4, 8, 16 or 600 (Z, switch selected.
4, 8, 16 or 600 (2 internal load, 10,000 SE across
external load,

3000 $2 (600 52 when shuntedwith750§z resistor).

60 cycles,
Approximately 6 kc.

Within 5% of full scale.
Within 10% of full scale,

Page 2

-HEATHKIT'

Gene

Multipliers. .
Meter

Meter Rectifier
Tube Complement

Page 3

ral:

...--.

......-.....

Precisiontype.

. . . . . . . . . . . . . 4-1/2" streamlined case with 200 microampere
movement.

. . . . . . . . . . . . . Germanium diode bridge.

............. 1-12AT7

1 - 12AU7
1 - 12AX7
1 - 6C4
1 - 6X4
Power Supply. , , , , . , . . . . . . , . . . . . . . Transformer, full wave rectifier.
Power Requirements. . . . . . . . . . . . . . . . 105-125 or 210-250 volts 50/60 cycles 20 watts,

Dimensions, . . ...... . . . . . . . . . . . . . . 13" wide x 8-1/2" highx 7" deep.
NetWeight....................... 9lbs.
The Heath Company reserves the right to dis-
continue instruments and to change specifica-
tions at any time without incurring any obliga-
tion to incorporate new features in instruments
previously sold,
I0 I00 IOOO IO KC IOOKC
+5 2357 2357 2357 2357 2357
one - fiE' ~'.
-5 i \J
\
-IO NOTE: ALL MEASUREMENTS TAKEN FROM
soon souncs. VTVM CURVES MEASUR- N
-I5 -_ ED FOR BEST AND POOREST RESPONSE \
(.OIV RANGE AND 3V RANGE RESPECTIVELY)
- 0 H T T FA
FRE UENCY C ARAC ERIS ICS WILL LL WATTMETER
BETWEEN THESE LIMITS ON ALL OTHER RANGES.
k 1 { I | l l I I 3V VTVM RANGE II----
MAXIMUM - .OIV VTVM RANGE -- --
MAXIMUM PERMISSIBLE PERMmsmLE -
LOW FREOUENCV HIGH FREQ.
OPERATING RANGE m) OPERATWG
l I$--RANGE-)1
0 A I Vs r! l g
I I.M. ANALVZER /I.M. ANALYZE \
5 LOW PASS FILTER / HIGH PASS \
-Io RESPONSE FILTER \
\ RESPONSE \
I5

-20

IMC