Harman kardon 100 plus service manual

This is the 34 pages manual for harman kardon 100 plus service manual.
Read or download the pdf for free. If you want to contribute, please mail your pdfs to info@audioservicemanuals.com.

Page: 1 / 34
left right
harman kardon 100 plus service manual

Extracted text from harman kardon 100 plus service manual (Ocr-read)


Page 2

ALIGNMENT PROCEDURES

AM IF AMPLIFIER ALIGNMENT PROCEDURE

INSTRUMENT: AM Generator (with Scope)
OUTPUT OF GENERATOR: Connect to TCS (On V,C. - AM 050) Terminal, Frequency = 455 KHz.

Adjust IFT51 and IFT52 as follows: -
Adjust "B" for Maximum
NOTE: Generator Signal must be kept as low as possible to avoid A.V.C. action. B
AM ALIGNMENT PROCEDURE

INSTRUMENT: AM Signal Generator, AC VTVM 8L Oscilloscope
NOTE: Set Function Switch to AM"
Set Mode Switch to MONO"
Set Volume Control to "MINIMUM"
Input Signal must be kept as low as possible to avoid A.V.C. action

' | G t '
Steps Signa enera or Tuning. D'al VTVM & Scope Adjustment Adjust for
Coupling Frequency Setting Connection
L52
1 515KH2 F'Fluency
Minimum
2 1650KHz Freqf'encv T05
Maxvmum
*3
OKH
The Test Loop GOOKHZ 60 1 L51
4 b t 60 m (2 n) 00" 30% (Bar Am)
a ou f c M B Modulation) '- Channel Tape Maximum
ail/av :wsA ar Out Terminal Amplitude
: °°'° c ' 1400KH2 1400KHz
5 ma (400H2, 30% T04
Modulation)
*6
7 TOOOKHZ 1000KHZ VR52 0.225V (HMS)
(400Hz. 30% Output
Modulation)
Generator Signal Meter
R 1
8 Output 0.1V V 5 Full Scale
*3 Repeat Steps 1 and 2 until no further improvement is noticed.
*5 Repeat Steps 4 and 5 until no further improvement is noticed.