Page 1
2
Contents
Safety Information ........................................................................\
..................................................... 3
Warranty........................................................................\
..................................................................... 3
Specifications ........................................................................\
............................................................ 4
Electrostatic Discharge Sensitive (ESDS) Device Handling ....................................................... 5
Part List Notes ........................................................................\
........................................ .................. 5
L1 Compact Accessory Pack ........................................................................\
............................. ...... 5
Product Description ........................................................................\
.................................... ......... 6-8
Packaging Part List, L1 Compact Power Stand (includes Array) (see Figure 1) ........................ 9
Figure 1. L1 Compact Power Stand Packaging View ........................................................................\
.. 9
Packaging Part List, L1 Compact Array Extensions (see Figure 2) .......................................... 10
Figure 2. L1 Compact Array Extensions Packaging View ................................................................. 10
Main Part List, L1 Compact Power Stand (see Figure 3) ....................................................... 1 1-12
Figure 3. L1 Compact Power Stand Exploded View ........................................................................\
.. 12
Main Part List, L1 Compact Array Speaker (see Figure 4) .......................................................... 13
Figure 4. L1 Compact Array Speaker Exploded View ........................................................................\
13
Main Part List, L1 Compact Array Extension Exploded View (see Figure 5) ............................ 14
Figure 5. L1 Compact Array Extension Exploded View ..................................................................... 14
Electrical Part List ........................................................................\
................................... ......... 15-37
Input/Output PCB Assembly ........................................................................\
............................ 15 -29
3.5mm Line Input PCB Assembly ........................................................................\
.......................... .29
Output PCB Assembly ........................................................................\
...................................... 29-30
Power Amplifier PCB Assembly ........................................................................\
....................... 31-3 7
Disassembly Procedures ........................................................................\
................................. 38-44
Test Procedures ........................................................................\
............................................... 45-48
IC Diagrams ........................................................................\
............................................ ........... 49-50
Service Manual Revision History ........................................................................\
........................ .51
Page 2
3
Safety Information
1. Parts that have special safety characteristics are identified by the \
symbol on schematics
or by special notes on the parts list. Use only replacement parts that have critical characteristics
recommended by the manufacturer.
2. Make leakage current or resistance measurements to determine that exposed parts are
acceptably insulated from the supply circuit before returning the unit to the \
customer.
Use the following checks to perform these measurements:
A. Leakage Current Hot Check-With the unit completely reassembled, plug the AC line cord
directly into a 120V AC outlet. (Do not use an isolation transformer during this test.) Use\
a
leakage current tester or a metering system that complies with American National Standards
Institute (ANSI) C101.1 "Leakage Current for Appliances" and Underwriters Laboratories (UL)
6500 / IEC 60056 paragraph 9.1.1. With the unit AC switch first in the ON position and then in
OFF position, measure from a known earth ground (metal waterpipe, conduit, etc.) to all ex-
posed metal parts of the unit (antennas, handle bracket, metal cabinet, screwheads, metallic
overlays, control shafts, etc.), especially any exposed metal parts that offer an electrical return
path to the chassis. Any current measured must not exceed 0.5 milliamp. Reverse the unit
power cord plug in the outlet and repeat test. ANY MEASUREMENTS NOT WITHIN THE
LIMITS SPECIFIED HEREIN INDICATE A POTENTIAL SHOCK HAZARD THAT MUST BE
ELIMINATED BEFORE RETURNING THE UNIT TO THE CUSTOMER.
B. Insulation Resistance Test Cold Check -(1) Unplug the power supply and connect a jumper
wire between the two prongs of the plug. (2) Turn on the power switch of the unit. (3) Measure
the resistance with an ohmmeter between the jumpered AC plug and each exposed metallic
cabinet part on the unit. When testing 3 wire products, the resistance measured to the product
enclosure should be between 2 and infinite MOhms. Also, the resistance measured to exposed
input/output connectors should be between 4 and infinite MOhms. When tes\
ting 2 wire prod-
ucts, the resistance measured to exposed input/output connectors should be between 4 and\
infinite MOhms. If it is not within the limits specified, there is the possibility of a shock hazard,
and the unit must be repaired and rechecked before it is returned to the customer.
CAUTION: The Bose ® L1 ® Compact system contains
no user-serviceable parts. To prevent warranty infractions,
refer servicing to warranty service stations or factory service.
PROPRIETARY INFORMATION
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF
BOSE CORPORATION WHICH IS BEING FURNISHED ONLY FOR
THE PURPOSE OF SERVICING THE IDENTIFIED BOSE PRODUCT
BY AN AUTHORIZED BOSE SERVICE CENTER OR OWNER OF
THE BOSE PRODUCT, AND SHALL NOT BE REPRODUCED OR
USED FOR ANY OTHER PURPOSE.
The Bose L1 Compact Power Stand is covered by a limited 2-year transferable warranty.
The L1 Compact Array and the Power Stand woofer are covered by a 5-year limited warranty.
Warranty