Audiolab 8200 q owners manual

This is the 6 pages manual for audiolab 8200 q owners manual.
Read or download the pdf for free. If you want to contribute, please mail your pdfs to info@audioservicemanuals.com.

Page: 1 / 6
left right
audiolab 8200 q owners manual

Extracted text from audiolab 8200 q owners manual (Ocr-read)


Page 2

Mains supply and safety Important notice to UK users Mains Supply: 8000Q: 220-240V: 100-120V 8000M: 220-240V: 100-120V 8000P: 220-240V: 4 100-120V Power Cord:The mains voltage of Audiolab units is shown on the rear panel. If this does not match the voltage in your area, consult your dealer. The mains supply fuse is on the rear panel. If it has broken, check for any obvious cause before replacing the fuse with one of the correct rating and type. The fuses for all areas are type T (time lag ) AL 20mm. The fuse values are: 1.0A : 1.6A 3.15A : 5.0A .0A : 5.0A The fuse is located in a slide-in carrier which also contains a spare fuse. The carrier can only be pulled out after the IEC power cord is unplugged. When the carrier is opened the first fuse is the spare. Remove and safely dispose of the blown fuse before replacing it. Class II construction double insulated. These products must not be connected to earth. An AC power cord is normally supplied with a mains plug suitable for your area. If you have any doubts, consult your dealer about obtaining a suitable power cord. The appliance cord is terminated with a UK approved mains plug fitted with a 5A fuse. If the fuse needs to be replaced, an ASTA or BSI approved BS1362 fuse rated at 5A must be used. If you need to change the mains plug, remove the fuse and dispose of this plug safely immediately after cutting it from the cord. Connecting a Mains Plug                                            !         "                   #$%  &'   "                 &'  (% 5A FUSE BS 1362 BROWN (Live) BLUE (Neutral)         ead these instructions. Keep these instructions. In the event that you pass the product to a third party this instruction manual should be provided along with the product. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with dry cloth. Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.Use only attachments/accessories specified by the manufacturer. Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. Unplug this apparatus during lightning storms or when unused for long periods of time. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power- supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. To reduce the risk of fire or electrical shock, do not expose this product to rain or moisture. The product must not be exposed to dripping and splashing and no object filled with liquids such as a vase of flowers should be placed on the product. No naked flame sources such as candles should be placed on the product. Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate this device. : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be determined by tuning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Re-orientate or re-locate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. The batteries supplied with the 8000Q handset should be treated with care and not punctured or damaged. Used batteries should be disposed of in full conformity with recycling regulations in your area. NEVER dispose of batteries in a fire or in the general rubbish. Warning: Caution: 8000Q Important Note: CAUTION!                                                       This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. 1: Statutory & Safety Information 8000Q Pre-amplifier 8000P Power Amplifier Inputs: Gain and Sensitivity Signal To Noise Ratio Frequency Response Total Harmonic Distortion & Noise Channel Balance Channel Separation Pre-amp Output Headphone Output Record Output Muting Operating Temperature Range Power Requirements Dimensions WeightRated Output Power Input Load Gain Signal To Noise Ratio Frequency Response Total Harmonic Distortion & Noise Channel Balance Polarity (Phase) Muting Operating Temperature Range Power Requirements Dimensions Weight CD, TUNER, AUX, VIDEO, TAPE 1, TAPE 2: IMPEDANCE: 20k GAIN: Adjustable by 3dB steps 0 -15dB., corresponding to SENSITIVITY(nom.): 100, 140mV, 200mV, 283mV, 400mV, 562mV HEADPHONES: Gain adjustable 18dB - 33dB in 3dB steps (IHF, rel. 0.5V output) Any input, any gain setting: 97dB Headphones: 80dB 10 Hz-20 kHz ±0.2 dB: 1 Hz-75 kHz -3 dB. Less than 0.007 % ref 7.7V rms, 20Hz - 20kHz Within 1 dB Better than100 dB @ 1 kHz any input, any setting Max. Output >7.7 V RMS (20dBm); Output impedance 75 >7.7Vrms;100 (for headphones 8 -2 k impedance) VIDEO OUT, TAPE 1 OUT, TAPE 2 OUT: Gain 0 dB (x1); 100 Attenuation>63 dB, controlled automatically 10-35 °C (Depending on Region) 50-60Hz 100V, 110-120V, and 220-240V models available Maximum Power Consumption: 15 VA (WXHXD) 445x74x335 mm - including feet, terminals and controls 445 x 64 x 302 mm- excluding feet, terminals and controls Net: 6 kg Shipping:7.3 kg100W (20dBW) /Channel into 8 both channels driven 1V rms for 100W into 8 Input Impedance: 50k Connected in parallel with INPUT 29.0 dB at1kHz (IHF, rel. 0.dBW) Better than 95 dB 20 Hz-20 kHz ±0.3 dB 0.1 Hz-75 kHz -3 dB. Less than 0.05 % Within 1 dB Non-Inverting Muting controlled automatically 10-35 °C (Depending on Region) 50-60 Hz 100V, 110-120V, and 220-240V models available Maximum Power Consumption: 500 VA (WXHXD) 445x74x337 mm - including feet, terminals and controls 445 x 64 x 302 mm- excluding feet, terminals and controls Net: 8.7 kg Shipping:10 kg 7: Specifications 8000M Power Amplifier Rated Output Power Input Sensitivity Load Gain Signal To Noise Ratio Frequency Response Total Harmonic Distortion & Noise Polarity (Phase) Muting Operating Temperature Range Power Requirements Dimensions Weight125W (21dBW) /Channel into 8 , 20Hz - 20kHz 1.12V rms for 120W into 8 Input Impedance: 50k Connected in parallel with INPUT 29.0 dB at1kHz (IHF, rel. 0.dBW) Better than 96 dB 20 Hz-20 kHz ±0.3 dB 0.1 Hz-75 kHz -3 dB. Less than 0.05 % Non-Inverting Muting controlled automatically 10-35 °C (Depending on Region) 50-60Hz 100V, 110-120V, and 220-240V models available Maximum Power Consumption: 300 VA (WXHXD) 445x74x337 mm - including feet, terminals and controls 445 x 64 x 302 mm- excluding feet, terminals and controls Net: 8.2 kg Shipping:9.6 kg Audiolab reserves the right to alter design and specification without notice. Specification may vary for different countries. Audiolab is a member of the International Audio Group.