Aiwa XK S7000 Service Manual

This is the 57 pages manual for Aiwa XK S7000 Service Manual.
Read or download the pdf for free. If you want to contribute, please mail your pdfs to info@audioservicemanuals.com.

Page: 1 / 57
left right
Aiwa XK S7000 Service Manual

Extracted text from Aiwa XK S7000 Service Manual (Ocr-read)


Page 39

IC, L065204A - 4540

Pin No. Pin Name I/O Description
1 WET/[.6 I Remote commander input
2 K — D A T A l I
3 K- DATA 2 I Analog data input of tactile key SW and push key SW
4 K — D A T A 3 I
5 S — D A T A l I
6 S 7 DATAZ I Analog data input of mechanical and AMTS detection SW
7 S — D A T A 3 I
8 A— DATA I Analog data input of MONITOR, CAL selector
9 AV 4" _ }AD converter voltage input terminal.
1 0 AV— __ Applies 5 V to AW and 0 V to AV-.
1 1 V S S — System power supply terminal. Connect to GND.
1 2 O S C 1 I System clock terminal.
1 3 O S C 2 0 Connect to a AMHz crystal clock.
1 4 VDD — System power supply terminal. +5 V connected.
1 5 m I System reset terminal
1 6 X I ‘I VDD connected.
1 7 X 2 0 Not connected.
1 8 TE ST I [.51 test terminal, Connect to GND.
1 9 m 0
2 O D—fi 0 FL light-up segment output. Lights up when [Lo].
2 1 W O
2 2 firs? I/O SD output/AC OFF detection to FL
2 3 W I Memory function Lo pulse input
2 4 I —R E E L I Auto stop reel pulse input
2 5 T—T-"P'L— I
}Mechanical cam position detection reef SW input
2 6 I — S - PA I
2 7 M— S L OW 0 Reel motor control output
2 8 M7 C A P S T O Capstan motor control output
2 9 M— R V S O } ,
Reel motor control output
3 O M— FWD 0
3 1 M— C L O S E O }
AMTS motor control output
3 2 M- O P E N O
3 3 S — P AU S E O PAUSE plunger control output
3 4 S — P L AY O PLAY plunger control output

Page 44

Pin No. Pin Name /0 Description
3 9 S EG 7 O "
4 O S E G 6 O
4 l S E G 5 O
4 2 S E G 4 O
4 3 S E G 3 0 FL light up segment output. Lights up when [H].
4 4 S E G 2 O
4 5 S E G 1 O
4 6 S E G O O _
4 7 GR I D 0 O _
4 8 GRID l 0
FL light up grid output. Lights up when [H].
4 9 GR I D 2 O
5 0 GR I D 3 O ‘
5 1 O — CAL 0 FL light up segment output. Lights up when [H].
5 2 VP v Pull down resistor load supply. Connect to —30V,

Note 1) PU refers to integrated pull
2) PC 0~3 and PD U~3 (Pin No.

up resistor and PD refers to integrated pull down resistor.
23~30) are [L] during the initial stage.